| Model | Power (kW) | Air Volume (m³/h) | Total Pressure (Pa) | Cartridge Quantity (pcs) | Filter Area (m²) | Dimensions L×W×H (mm) | Weight (kg) |
| PTL 10000 | 15 | 10000—15000 | 2500-2800 | 16 | 140 | 2900 *1008 *4550 | 1200 |
| PTL 20000 | 22 | 20000—25000 | 2500-2800 | 32 | 280 | 2900 *2016 *4550 | 2400 |
| PTL 30000 | 30 | 30000—35000 | 2500-2800 | 48 | 420 | 2900 *3024 *4550 | 3600 |
| PTL 40000 | 37 | 40000—45000 | 2500-2800 | 64 | 560 | 2900 *4032 *4550 | 4800 |
| PTL 50000 | 55 | 50000—55000 | 2500-2800 | 80 | 700 | 2900 *5040 *4550 | 6000 |
| PTL 60000 | 75 | 60000—65000 | 2500-2800 | 96 | 840 | 2900 *6048 *4550 | 7400 |
| Note: For units with an air volume exceeding 60,000 m³/h, a multi-unit connected configuration or on-site assembly is adopted to accommodate shipping and installation requirements. | |||||||
| Optional Accessories | A. Explosion-Proof Electrical Components B. Explosion Venting/Isolation C. Specialized Filter Cartridges D. Custom Coating/Finish F. Adapted Ductwork G. Weather Protection Canopy H. Maintenance Platform | ||||||
1.Filtration area: 140 m²; Filtration velocity: 0.02 m/s; Filtration efficiency: ≥99.95%; 16 pcs Ø325×660 cartridges;
2.Air volume: 10,000-15,000 m³/h; Fan pressure: Total pressure 2600 Pa;
3.Particulate emission: 4-20 mg/m³ (varies with cartridge material);
4.Inlet temperature requirement: Below 60℃;
5.Inlet concentration limit: Below 800 mg/m³ (cyclone pre-treatment required if exceeded);
6.Operating resistance: No-load (20°C): 300-600 Pa; Normal operation: 300-1500 Pa;
7.Total weight: Approx. 1200 kg;
8.Total power: 15 kW;
9.Power supply: 380V AC, 50Hz;
10.Air supply pressure: 0.5-0.6 MPa; Flow rate: >0.5 m³/min;
11.Noise: <75 dB at 1 m (with silencer; excluding pulse-jet cleaning noise);
12.Dimensions: See attached drawing.
|
Enclosure Structure |
Q235 Carbon Steel, 2-10mm |
|
|
Surface Treatment |
Powder Coating, 60-120μm PT Blue |
|
|
Pulse Valve |
Standard Pulse-Jet Valve |
|
|
HMI & PLC |
Touchscreen PLC Interface |
Optional |
|
Centrifugal Fan |
High-Efficiency Fan Unit |
|
|
Switchgear |
Standard Electrical Components |
|
|
Sensors |
Industrial-Grade Sensors |
|
|
Control Cabinet |
Custom Built |
|
| No. | Configuration Item | PLT-10000 Standard |
| Standard Factory Configuration | ||
|
1 |
Main Structural Frame (Carbon Steel), approx. 1000 kg |
● |
|
2 |
Standard Membrane Filter Cartridges, 325×660mm, 16 pcs |
● |
|
3 |
Centrifugal Fan, 15 kW, Q=10,000-15,000 m³/h, 2600-3500 Pa |
● |
|
4 |
Basic Control Cabinet (Push Buttons + Star-Delta Starter) |
● |
|
5 |
Motorized Continuous Discharge Valve |
● |
|
7 |
Standard Hardware & Assembly Components |
● |
|
8 |
Surface Treatment (Powder Coating 60-120μm, PT Standard Color) |
● |
| Optional / Upgrade Items | ||
|
1 |
Safety Guardrails & Maintenance Ladder |
○ |
|
2 |
Fan-to-Unit Connection Ductwork |
○ |
|
3 |
Cyclone Separator (Model: XFT950) |
○ |
|
4 |
Air Volume Control Damper |
○ |
|
5 |
PLC with VFD (Variable Frequency Drive) Control System |
○ |
|
6 |
Anti-Static Membrane Filter Cartridges (16 pcs) |
○ |
|
7 |
Custom Paint Color or 10-Year Long-Term Anti-Corrosion Coating (C4) |
○ |
|
8 |
Explosion-Proof Low-Noise Centrifugal Fan (Exd IIB) |
◎ |
|
9 |
Explosion-Proof Electrical Control System (Exd IIB) |
◎ |
|
10 |
Integrated Automatic Water Spray System |
◎ |
|
11 |
Explosion Isolation & Venting System (Isolation, Pressure Venting) |
◎ |
|
12 |
Spark Detection System + Duct Spray + Booster Pump (2 detectors + 1 spray unit) |
◎ |
|
● Standard Factory Configuration ○ Optional / Upgrade ◎ Explosion-Proof & Flame-Retardant Option |
||